www.delorie.com/archives/browse.cgi   search  
Mail Archives: geda-user/2017/08/14/23:29:46

X-Authentication-Warning: delorie.com: mail set sender to geda-user-bounces using -f
X-Recipient: geda-user AT delorie DOT com
Date: Tue, 15 Aug 2017 05:30:20 +0200 (CEST)
X-X-Sender: igor2 AT igor2priv
To: geda-user AT delorie DOT com
X-Debug: to=geda-user AT delorie DOT com from="gedau AT igor2 DOT repo DOT hu"
From: gedau AT igor2 DOT repo DOT hu
Subject: Re: [geda-user] [pcb] mainline: redundant attributes: bug or
feature?
In-Reply-To: <xnshgty1ey.fsf@envy.delorie.com>
Message-ID: <alpine.DEB.2.00.1708150521370.27212@igor2priv>
References: <xnshgty1ey DOT fsf AT envy DOT delorie DOT com>
User-Agent: Alpine 2.00 (DEB 1167 2008-08-23)
MIME-Version: 1.0
Reply-To: geda-user AT delorie DOT com
Errors-To: nobody AT delorie DOT com
X-Mailing-List: geda-user AT delorie DOT com
X-Unsubscribes-To: listserv AT delorie DOT com


On Mon, 14 Aug 2017, DJ Delorie wrote:

>
> gedau AT igor2 DOT repo DOT hu writes:
>> I did not find any sign that the import sch would set element attributes -
>> maybe that was the plan, to import attributes from the schematics, but it
>> never happened? Does the pcb netlist format even support that?
>
> File->Import doesn't use a netlist, it uses an action script.  That
> script sets element attributes from symbol attributes.

Ahh, thanks, indeed, the gnetlist backend generates the 
script and that will probably have ElementSetAttr() actions for setting 
element attributes.

That's good news: I think that action never permitted redundant keys, at 
least neither in the 2011 version nor in 4.0.0. So I think pcb never 
really supported redundant key imported via gnetlist so making it an 
explicit error won't change anyone's flow.