www.delorie.com/archives/browse.cgi   search  
Mail Archives: geda-user/2018/02/03/11:02:31

X-Authentication-Warning: delorie.com: mail set sender to geda-user-bounces using -f
X-Recipient: geda-user AT delorie DOT com
Subject: Re: [geda-user] Net length info question
To: geda-user AT delorie DOT com
References: <0a59af1c-d27e-2b2f-f649-fd5f84ae7fc5 AT linetec DOT nl>
<20180203161104 DOT 041fb36a17997541ea44b220 AT gmail DOT com>
From: "Richard Rasker (rasker AT linetec DOT nl) [via geda-user AT delorie DOT com]" <geda-user AT delorie DOT com>
Message-ID: <22dbfa1f-39de-dced-f24a-451804d75d65@linetec.nl>
Date: Sat, 3 Feb 2018 17:01:06 +0100
User-Agent: Mozilla/5.0 (X11; Linux x86_64; rv:52.0) Gecko/20100101
Thunderbird/52.6.0
MIME-Version: 1.0
In-Reply-To: <20180203161104.041fb36a17997541ea44b220@gmail.com>
X-MIME-Autoconverted: from quoted-printable to 8bit by delorie.com id w13G1R5d019647
Reply-To: geda-user AT delorie DOT com
Errors-To: nobody AT delorie DOT com
X-Mailing-List: geda-user AT delorie DOT com
X-Unsubscribes-To: listserv AT delorie DOT com


Op 03-02-18 om 16:11 schreef Nicklas Karlsson 
(nicklas DOT karlsson17 AT gmail DOT com) [via geda-user AT delorie DOT com]:
> On Sat, 3 Feb 2018 14:57:56 +0100
> "Richard Rasker (rasker AT linetec DOT nl) [via geda-user AT delorie DOT com]" <geda-user AT delorie DOT com> wrote:
>
>> Hi all,
>>
>> Maybe a rather unusual question, but at the moment, I'm "abusing" PCB in
>> the construction of our new home, intended to rely on 100% solar energy:
>> we plan to use the ground under the house for storing heat, by laying 3
>> lengths of 100 m (~300 ft) of tubing in the foundations as a heat pump
>> source.
> You might get a problem in case your heat pump cool your foundation below zero degree Celsius?

Yeah, I know, but those things are covered -- I've hired a professional 
who doesn't just supply the hardware (heat pump, PVT panels etcetera -- 
although I'll build the system controller myself), but who also helped 
design and calculate the whole system.

For most of the time, the heat pump draws its source straight from the 
heat exchangers on the solar panels. The subterranean heat storage is 
only used when the solar panels get below freezing point, and as we have 
a mild sea climate here in the Netherlands, this happens a few weeks per 
year at most. With a heat storage of ~100 cubic meters of water at 20°C 
and a very well insulated house, we should be good for about a month of 
icy, low daylight (cloud cover) conditions before this source runs low.

Also, the heat pump switches to a built-in electric heater spiral if the 
source temperature gets too low. This, of course, is far less efficient, 
but the fact that we'll be selling surplus electricity back to the grid 
for most of the year more than makes up for the (hopefully) very rare 
occasions that this happens. And oh, there's also still the central 
fireplace.

But it's exciting all the same, and I really hope that our calculations 
and estimates pan out!