www.delorie.com/archives/browse.cgi   search  
Mail Archives: geda-user/2017/06/18/11:38:34

X-Authentication-Warning: delorie.com: mail set sender to geda-user-bounces using -f
X-Recipient: geda-user AT delorie DOT com
X-Mailer: exmh version 2.8.0 04/21/2012 (debian 1:2.8.0~rc1-2) with nmh-1.5
X-Exmh-Isig-CompType: repl
X-Exmh-Isig-Folder: inbox
From: karl AT aspodata DOT se
To: geda-user AT delorie DOT com
Subject: Re: [geda-user] DIY PCBs
In-reply-to: <efa75d25-7cfd-49a8-cec5-7522a80ee010@ecosensory.com>
References: <20170617081144 DOT 16928 DOT qmail AT rahul DOT net> <efa75d25-7cfd-49a8-cec5-7522a80ee010 AT ecosensory DOT com>
Comments: In-reply-to "John Griessen (john AT ecosensory DOT com) [via geda-user AT delorie DOT com]" <geda-user AT delorie DOT com>
message dated "Sat, 17 Jun 2017 16:38:47 -0500."
Mime-Version: 1.0
Message-Id: <20170618153703.D607D801F77A@turkos.aspodata.se>
Date: Sun, 18 Jun 2017 17:37:03 +0200 (CEST)
X-Virus-Scanned: ClamAV using ClamSMTP
Reply-To: geda-user AT delorie DOT com
Errors-To: nobody AT delorie DOT com
X-Mailing-List: geda-user AT delorie DOT com
X-Unsubscribes-To: listserv AT delorie DOT com

John Griessen:
> On 06/17/2017 03:11 AM, John Conover wrote:
...
> > http://www.johncon.com/john/PCB/
...
> I also use air regeneration of the CuCl2, which might even reduce the amount of HCl needed,
> but that's not a very big cost anyway.  It does skip the need for any H2O2 buying
> except to get started quickly.   Air bubbling of copper wire under HCl will get you
> a charged up  CuCl2 bath eventually.  DJ Delorie gets credit for the CuCl2 chemistry
> efficiency details.

I usually use natriumperoxidisulfate for etching, would there be any
advantage to use H2O2/HCl instead ?

///

I found a comparision of etching baths re. danger in [1] which
says that H2O2/HCl produces toxic gases.

[2] says that natriumperoxidisulfate can produce finer structures
than Fe(III)Cl.

[3] proposes citric acid (sounds very slow).

[4], p. 7 indicates that Fe(III)Cl is 6 times faster than H202/HCl, and
peroxidifulfate is inbetween (3600 / 2500 / 600 nm/min).

[5], uses Acetic Acid and Hydrogen Peroxide and is a little slower 
(200nm/min).

[6] states that perdisulphate is cleaner and safer than Fe(III) and
H202 variants.

Has anyone tried electrolysis as in [7], [8] ?

[9] uses CuCl which can be regenerated, but has more undercut according
to [10].

Regards,
/Karl Hammar

[1]  https://web.archive.org/web/20090907183632/http://www.tuf-ev.de/workshop/aetzen/EntsorgungAetzen.htm
[2]  https://de.wikipedia.org/wiki/Natriumpersulfat
[3]  http://transene.com/wp-content/uploads/Copper-Etch-Article.pdf
[4]  https://nanolab.berkeley.edu/labmanual/chap1/JMEMSEtchRates2(2003).pdf
[5]  http://engineering.tufts.edu/microfab/documents/SOP_CopperEtch2.pdf
[6]  http://sfprime.net/pcb-etching/
[7]  http://nontoxicprint.com/electroetching.htm
[8]  https://en.wikipedia.org/wiki/Electrolysis
[9]  http://www.goldrecovery.us/goldrecovery/documents/CuCl.pdf
[10] http/www.chemcut.net/wp-content/uploads/2015/03/Chemcut_Bulletin_8_Cupri_Chloride_Proces_-Parameters.pdf

-----------------------------------------------------------------------