www.delorie.com/archives/browse.cgi   search  
Mail Archives: geda-user/2015/09/23/04:43:27

X-Authentication-Warning: delorie.com: mail set sender to geda-user-bounces using -f
X-Recipient: geda-user AT delorie DOT com
X-Injected-Via-Gmane: http://gmane.org/
To: geda-user AT delorie DOT com
From: Kai-Martin Knaak <knaak AT iqo DOT uni-hannover DOT de>
Subject: Re: [geda-user] gschem, best size of symbols and text?
Date: Wed, 23 Sep 2015 10:42:38 +0200
Organization: Institut =?UTF-8?B?ZsO8cg==?= Quantenoptik
Lines: 82
Message-ID: <mttolv$d52$1@ger.gmane.org>
References: <1442845842 DOT 2167 DOT 27 DOT camel AT ssalewski DOT de>
Mime-Version: 1.0
X-Complaints-To: usenet AT ger DOT gmane DOT org
X-Gmane-NNTP-Posting-Host: 130.75.102.197
User-Agent: KNode/4.14.1
X-MIME-Autoconverted: from quoted-printable to 8bit by delorie.com id t8N8h3K6010468
Reply-To: geda-user AT delorie DOT com

Stefan Salewski wrote:

> What do you think about gschems symbol and text size? Is it optimal?

IMHO, this is a matter of style and taste. Therefore it cannot be decided 
based on purely rational arguments. There is quite a range of acceptable 
relative sizes. And there are traditions. Note the plural. :-) 


> I
> can remember that some people complained that symbols are too large
> some years ago.

Well, I was none of the complainers. In fact, I like the symbol size to 
text relation in the default library. Note, I am talking about the size of 
the symbol excluding the pins. The pins seem rather large in the default 
lib. This makes for unnecessarily awkward positioning if space is tight.


> But now I get the feeling that basic symbols (resistor, capacitor, ...)
> are indeed too large compared to the default 100 grid size. Resistor is
> 900 units in length, so for default 100 grid it can be placed in 9
> steps on his own area.

The resistors in my library are the same size when it comes to their body. 
But their pins are 100 units rather than 300. So my resistors end up 600 
units from hot spot to hot spot. Same with capacitors.


> Or, compared to the symbol size, default 100
> grid is too small. Making 200 grid the default does not work well,
> because 900 is odd. And indeed I think that 100 is a nice default grid
> size. So I consider shrinking the basic symbols. For screen display, I
> prefer 10 units for general line width, and currently I like 600 units
> for total resistor length. See http://ssalewski.de/PetEd.html.en

I prefer the European/Asian style of resistors as defined in DIN EN 60617
This standard uses boxes rather than zig-zag lines. The length of pins in 
the artwork of a resistor symbol in the standard are 1/6 of the length of 
the box. This is even shorter than the pins in my library.

 
> Note: On that picture you can see the 9 gray position marker crosses
> which are displayed when mouse pointer hovers over a text element. You
> can press MMB over one of them to change alignment of text. I like it.

+1
Many CAD programs feature similar markers of whatever a click would refer 
to at the current position of the mouse. Usability of PCB could benefit 
from such visual hints, too.

---<)kaimartin(>---
-- 
Kai-Martin Knaak                                  tel: +49-511-762-2895
Universität Hannover, Inst. für Quantenoptik      fax: +49-511-762-2211	
Welfengarten 1, 30167 Hannover           http://www.iqo.uni-hannover.de
GPG key:    http://pgp.mit.edu:11371/pks/lookup?search=Knaak+kmk&op=get