www.delorie.com/archives/browse.cgi   search  
Mail Archives: geda-user/2015/07/13/15:20:26

X-Authentication-Warning: delorie.com: mail set sender to geda-user-bounces using -f
X-Recipient: geda-user AT delorie DOT com
X-Virus-Scanned: amavisd-new at neurotica.com
X-NSA-prism-xkeyscore: I do not consent to surveillance, prick
X-Original-DKIM-Signature: v=1; a=rsa-sha256; c=relaxed/simple; d=neurotica.com;
s=default; t=1436815180;
bh=MiCWs61jj33SG+22iHfHP3g5+3XxaDT9TpWJN9CwfDA=;
h=Date:From:To:Subject:References:In-Reply-To;
b=E6XSu4C1JrmmHAHu7JZdxCXq26KMSjAWVI9NuIjDJQoL3K0g0XZSwHnoZmKDgFMae
pxgljZRrCw/z8JqQNBhrmr6X2FlB/ZkR8LVLeo5f0dyECFy7Z+ZLrfumv/spUhO2Jh
qS20qkkFpqHr69IeBG/+QkjEPgcLb/5ZSrixv5Rc=
Message-ID: <55A40F4C.8020205@neurotica.com>
Date: Mon, 13 Jul 2015 15:19:40 -0400
From: "Dave McGuire (mcguire AT neurotica DOT com) [via geda-user AT delorie DOT com]" <geda-user AT delorie DOT com>
User-Agent: Mozilla/5.0 (X11; Linux x86_64; rv:31.0) Gecko/20100101 Thunderbird/31.7.0
MIME-Version: 1.0
To: geda-user AT delorie DOT com
Subject: Re: [geda-user] PCB interface (ECAD vs. MCAD)
References: <76520AC3-3E8D-4F80-A912-AB076DD8D0C6 AT icloud DOT com> <1670171546 DOT 913210 DOT 1436776811789 DOT JavaMail DOT yahoo AT mail DOT yahoo DOT com> <79456AAA-24A9-4300-900D-005ABBCFCBDA AT icloud DOT com> <CAOP4iL0dWqVnAXRSfYKRW4BknJ5WK5oFceSg7TWcb3m57oUesA AT mail DOT gmail DOT com> <871tgb99sm DOT fsf AT rover DOT gag DOT com>
In-Reply-To: <871tgb99sm.fsf@rover.gag.com>
Reply-To: geda-user AT delorie DOT com

On 07/13/2015 02:44 PM, Bdale Garbee wrote:
> "Ouabache Designworks (z3qmtr45 AT gmail DOT com) [via
> geda-user AT delorie DOT com]" <geda-user AT delorie DOT com> writes:
> 
>> And schematic capture is a single layer PCB with minimal widths
>> and thickness where  lines crossing at right angles do not
>> connect.
> 
> Ah, no.  To me, at least.  Schematic capture is about creating and 
> maintaining documentation for a set of objects, their connectivity,
> and arbitrary attributes attached to the parts and/or their 
> connectivity. What a schematic *looks like* is almost irrelevant...
> ;-)

  Heh...until you try to repair something. ;)

  Today's trendy schematics seem to consist almost exclusively of
boxes with netnames attached to pins, and few if any lines.  Just try
troubleshooting something with that, it's almost useless!

               -Dave

-- 
Dave McGuire, AK4HZ
New Kensington, PA