www.delorie.com/archives/browse.cgi   search  
Mail Archives: geda-help/2013/12/19/01:08:42

X-Authentication-Warning: delorie.com: mail set sender to geda-help-bounces using -f
Date: Thu, 19 Dec 2013 01:08:32 -0500
Message-Id: <201312190608.rBJ68W4d021122@envy.delorie.com>
From: DJ Delorie <dj AT delorie DOT com>
To: geda-help AT delorie DOT com
In-reply-to:
<CALT8Ef5XtuaPY4QjAw=658ZaL_sV38CbX0aqgosRvOVdG5BmKA AT mail DOT gmail DOT com>
(message from Shashank Chintalagiri on Thu, 19 Dec 2013 11:11:09
+0530)
Subject: Re: [geda-help] PCB segfault on opening specific PCBs
References: <CALT8Ef5XtuaPY4QjAw=658ZaL_sV38CbX0aqgosRvOVdG5BmKA AT mail DOT gmail DOT com>
Reply-To: geda-help AT delorie DOT com

Looks like CreateNewNet() has a hardcoded limit of 63 characters for
net names, but doesn't check the length coming from the schematic.
Did you add or rename a net using a long name?  Or are you using
heirarchy?

(and yes, please add a bug report to launchpad if there isn't one already)

- Raw text -


  webmaster     delorie software   privacy  
  Copyright © 2019   by DJ Delorie     Updated Jul 2019