"John Henderson" <jhenRemoveThis AT bigpond DOT com> said:

> But I've been unable to discover how to "read" the associated IRQ
> value for each port.  So far I've found them hardcoded as 4, 3,
> 4, 3 respectively in all examples.  But I've got to look no
> further than my own PC to find COM3 using IRQ5 (on an ISA card).
> How does a program discover this?

Only way I know is to 
1. mask off all interrupts in the PIC (to prevent false positives)
2. clear the in-service bits
3. issue an UART command that raises it's IRQ line (e.g. an internal 
  loopback test)
4. poll all in-service bits in the PIC
5. and finally restore the PIC mask.

A lot of work to automate. A IMHO nicer approach would be to
use an environment variable so the user can override default assumptions.
E.g. COM1_SETTINGS=irq 5, base 0x3f8

Gisle V.