www.delorie.com/archives/browse.cgi   search  
Mail Archives: geda-user/2021/02/05/15:08:13

X-Authentication-Warning: delorie.com: mail set sender to geda-user-bounces using -f
X-Recipient: geda-user AT delorie DOT com
X-Originating-IP: 88.129.21.118
Subject: Re: [geda-user] Power and IO symbols
To: geda-user AT delorie DOT com
References: <alpine DOT DEB DOT 2 DOT 21 DOT 2012090007290 DOT 1129 AT nimbus>
<20201209065927 DOT 985928512091 AT turkos DOT aspodata DOT se>
<alpine DOT DEB DOT 2 DOT 21 DOT 2012091414150 DOT 1205 AT nimbus>
From: "Nicklas SB Karlsson (nk AT nksb DOT online) [via geda-user AT delorie DOT com]" <geda-user AT delorie DOT com>
Message-ID: <a0c0c277-78de-e879-9562-bfc5c8b25c42@nksb.online>
Date: Fri, 5 Feb 2021 20:47:36 +0100
User-Agent: Mozilla/5.0 (X11; Linux x86_64; rv:78.0) Gecko/20100101
Thunderbird/78.7.0
MIME-Version: 1.0
In-Reply-To: <alpine.DEB.2.21.2012091414150.1205@nimbus>
Reply-To: geda-user AT delorie DOT com
Errors-To: nobody AT delorie DOT com
X-Mailing-List: geda-user AT delorie DOT com
X-Unsubscribes-To: listserv AT delorie DOT com

Den 2020-12-09 kl. 14:33, skrev Roland Lutz:
> On Wed, 9 Dec 2020, karl AT aspodata DOT se [via geda-user AT delorie DOT com] wrote:
>> The netif_*.sym ones are useful in a subschematic. The vertical line 
>> marks the border/end/interface of a subschematc. Also I like the 
>> thicker line for power sym.
>
> Looking at these symbols, I see what you mean: your port symbols are 
> at the same time net symbols, so for example, an input called "in1" is 
> connected to the net called "in1" in the subschematic.
>
> Seeing how net and port symbols are now identical except for the 
> netname= / portname= attribute, I wonder if it may be a good idea to 
> remove this distinction and connect the pin of an instantiating 
> component not to a *component*, but to a *net* in the subschematic.
>
> Up until now, when a subschematic component is hooked up to the 
> subschematic(s) it instantiated, a pin with pinlabel=in1 on that 
> component is connected to a component with portname=in1 (or 
> refdes=in1) inside the subschematic.  This would change so it is 
> connected to the net named `in1' inside the subschematic.
>
> Pro: The confusion between netname= and portname= is resolved by 
> actually making it the same thing.

No do not think so then sub schematic is instantiated more than once, or?


Nicklas Karlsson

- Raw text -


  webmaster     delorie software   privacy  
  Copyright © 2019   by DJ Delorie     Updated Jul 2019