Date: Thu, 5 Mar 2015 20:03:12 +0100
From: Gabriel Paubert <paubert AT iram DOT es>
To: geda-user AT delorie DOT com
Subject: Re: [geda-user] [OT] Temperature sensor and control recommendation
Message-ID: <20150305190312.GA31466@visitor2.iram.es>
References: <CAF3uCZ=G0FztqBtpfvssYCz9WrUORX8+J45xmH9+KutaX6c+gw AT mail DOT gmail DOT com>
<201503051621 DOT t25GL09H018380 AT envy DOT delorie DOT com>
<54F88BAE DOT 3040606 AT ecosensory DOT com>
MIME-Version: 1.0
In-Reply-To: <54F88BAE.3040606@ecosensory.com>
User-Agent: Mutt/1.5.21 (2010-09-15)
X-Spamina-Bogosity: Unsure
X-Spamina-Spam-Score: -0.2 (/)
X-Spamina-Spam-Report: Content analysis details: (-0.2 points)
pts rule name description
---- ---------------------- --------------------------------------------------
-1.0 ALL_TRUSTED Passed through trusted hosts only via SMTP
0.8 BAYES_50 BODY: Bayes spam probability is 40 to 60%
[score: 0.4997]
Reply-To: geda-user AT delorie DOT com
Errors-To: nobody AT delorie DOT com
X-Mailing-List: geda-user AT delorie DOT com
X-Unsubscribes-To: listserv AT delorie DOT com

On Thu, Mar 05, 2015 at 11:00:30AM -0600, John Griessen wrote:
> On 03/05/2015 10:21 AM, DJ Delorie wrote:
> >I use the same averaging trick on my thermostats to get 0.1F readings
> >on a 1C-rated sensor.  If your sensor isn't noisy enough to use this
> >trick, you can always add noise - you're basically building a 1-bit
> >ADC.
> 
> The extra noise lets you explore the single bit crossings of your system statistically.
> Then you get out of the trap of temperature varying, but not seen crossing single bits
> of the system ADC.

That's called dithering and it's used on instruments like low frequency
spectrum analysers to increase dynamic range. I remember one HP spectrum
analyser from the time when these things were carefully documented,
adding some bandpass-limited noise around the Nyquist frequency of the sampler
but above the displayed frequency range (which was only a quarter of the
sampling frequency if I remember correctly).

But for very low frequencies, I would these days consider either a high
resolution delta-sigma ADC (LTC24xx for example but there are many
others), or a time proven solution like a VFC (voltage to frequency
converter). Monostable based VFC need a high stability capacitor to work
properly, but synchronous V/F (AD652, AD774x) do not need any critical
component, and with only two wires for the interface, are easy to
isolate galvanically or optically.