www.delorie.com/archives/browse.cgi   search  
Mail Archives: geda-user/2012/08/18/14:41:04

X-Authentication-Warning: delorie.com: mail set sender to geda-user-bounces using -f
X-Recipient: geda-user AT delorie DOT com
X-Mailer: exmh version 2.7.2 01/07/2005 (debian 1:2.7.2-18) with nmh-1.3
X-Exmh-Isig-CompType: repl
X-Exmh-Isig-Folder: inbox
To: geda-user AT delorie DOT com
Subject: Re: [geda-user]
In-reply-to: <CACPio-5yU_r49y5NcGK-9gHTPwuXmM17Cx_Qdigx_mnzcx7Z1w@mail.gmail.com>
References: <CACPio-6k5KWuEeHhn=1r8mxYb2HRpXzC5DrTWSaqDxufw7u2YQ AT mail DOT gmail DOT com> <k0jl2k$ibn$1 AT ger DOT gmane DOT org> <CACPio-4unK57Re-HUn_yyhBTt-P-Fph5B0cmVnE6gBzYnXUyww AT mail DOT gmail DOT com> <20120817161012 DOT GA28947 AT localhost DOT localdomain> <CACPio-5yU_r49y5NcGK-9gHTPwuXmM17Cx_Qdigx_mnzcx7Z1w AT mail DOT gmail DOT com>
Comments: In-reply-to Nathan Stewart <therealnathanstewart AT gmail DOT com>
message dated "Sat, 18 Aug 2012 10:29:15 -0400."
Mime-Version: 1.0
Message-Id: <20120818184020.87DC7801FC27@turkos.aspodata.se>
Date: Sat, 18 Aug 2012 20:40:18 +0200 (CEST)
From: karl AT aspodata DOT se (Karl Hammar)
X-Virus-Scanned: ClamAV using ClamSMTP
Reply-To: geda-user AT delorie DOT com
Errors-To: nobody AT delorie DOT com
X-Mailing-List: geda-user AT delorie DOT com
X-Unsubscribes-To: listserv AT delorie DOT com

Nathan Stewart:
> Apparently, the INPUT and IO components need to have a value=INPUT or
> value=IO. I also had issues with the net= attributes on my power pins
> - I had them labeled +7V and -7V, and at least -7V is not legal.  So I
> replaced them all with Vdd and Vss, even though emotionally I'm going
> 'but but but there's nothing in the circuit that says it has to be
> MOSFET!!!") and I secretly know in my heart that these represent a +/-
> 7V split rail supply.

It is my understanding that the pinlabel of the sym in the "upper" sch
has to match the refdes of a pin in the "lower" sch. That is what I
found out from [1].

I tested this in [2] (look for files hier.sch etc.).

There i no use of "value=INPUT" or "IO" needed and "-5V" works just as
well as "+5V".

Regards,
/Karl Hammar

[1] http://www.easy-asic.de/downloads/HOWTO_hierarchical_designs.pdf 
[2] http://turkos.aspodata.se/git/openhw/pdftosym/examples.pintosym/

-----------------------------------------------------------------------
Aspö Data
Lilla Aspö 148
S-742 94 Östhammar
Sweden
+46 173 140 57


- Raw text -