| www.delorie.com/archives/browse.cgi | search |
| X-Authentication-Warning: | delorie.com: mail set sender to geda-user-bounces using -f |
| X-Recipient: | geda-user AT delorie DOT com |
| X-Mailer: | exmh version 2.8.0 04/21/2012 with nmh-1.7+dev |
| X-Exmh-Isig-CompType: | repl |
| X-Exmh-Isig-Folder: | inbox |
| From: | karl AT aspodata DOT se |
| To: | geda-user AT delorie DOT com |
| Subject: | Re: [geda-user] finding unnamed_net35 |
| In-reply-to: | <5029D88F-B9B8-43D6-A2F5-BC5DB12B9932@ece.orst.edu> |
| References: | <5029D88F-B9B8-43D6-A2F5-BC5DB12B9932 AT ece DOT orst DOT edu> |
| Comments: | In-reply-to "Roger Traylor (traylor AT engr DOT orst DOT edu) [via geda-user AT delorie DOT com]" <geda-user AT delorie DOT com> |
| message dated "Wed, 05 Feb 2020 22:16:33 -0800." | |
| Mime-Version: | 1.0 |
| Message-Id: | <20200206080628.B46FB8A02BA8@turkos.aspodata.se> |
| Date: | Thu, 6 Feb 2020 09:06:28 +0100 (CET) |
| X-Virus-Scanned: | ClamAV using ClamSMTP |
| Reply-To: | geda-user AT delorie DOT com |
| Errors-To: | nobody AT delorie DOT com |
| X-Mailing-List: | geda-user AT delorie DOT com |
| X-Unsubscribes-To: | listserv AT delorie DOT com |
Roger Traylor:
> I can pass a schematic drc check (-g drc2) with one error which says:
> Checking type of pins connected to a net...
> ERROR: Net unnamed_net35 is not driven.
> I do not find this net in the .sch file anywhere. How can I find it?
It isn't in the sch since it is named in gsch2pcb or "import
schematics" phase.
If you have a *.net file, grep for it:
$ grep unnamed_net35 joystick_mouse_isolated.net
br/unnamed_net35 brU1-1 brC1-1
Else it is in the pcb file, but it is more than one line:
$ grep -A4 unnamed_net35 joystick_mouse_isolated.pcb
Net("br/unnamed_net35" "(unknown)")
(
Connect("brC1-1")
Connect("brU1-1")
)
Regards,
/Karl Hammar