www.delorie.com/archives/browse.cgi | search |
X-Authentication-Warning: | delorie.com: mail set sender to geda-user-bounces using -f |
X-Recipient: | geda-user AT delorie DOT com |
X-Original-DKIM-Signature: | v=1; a=rsa-sha256; c=relaxed/relaxed; |
d=gmail.com; s=20120113; | |
h=mime-version:in-reply-to:references:date:message-id:subject:from:to | |
:content-type; | |
bh=xf1mcSXGape1S6tyFZLS+rVvulrToPGymy5IIf58dfA=; | |
b=indTd3upwItiHthAc+xvvSHttSV/zcw5YubBtpXKuDimHaNpgX7sCjUeg9jUq63suu | |
HC/qSP9asRE93/qD0N3p4tdfWUGkhtY8IdJDKBCtYbZXtYjsziOkUq3P7N0B4GrnDben | |
9IqOCts6glQa4Xab8YejHUTgFn5n1SPOSJqDo5MttQmJeOThgcJ/lGij9TVvmod1ni9v | |
HFHN24UZdSgHOxF5SGxDnM4PBbsh0BhWFobON0EjjGbd9Rc4RZx68gjvFl3k9BpQdQ12 | |
vKGutfR3jUS59cdMX8ZsOFFENLLXrs0i76aFaihsE0s5rkPnf1k92kLVhuMxloMQrDMl | |
/ALw== | |
MIME-Version: | 1.0 |
X-Received: | by 10.112.212.9 with SMTP id ng9mr37942918lbc.57.1435961811244; |
Fri, 03 Jul 2015 15:16:51 -0700 (PDT) | |
In-Reply-To: | <8376edcac9694d2dc0d4195b4810ff45@cam.ac.uk> |
References: | <1435872894 DOT 31269 DOT 7 DOT camel AT cam DOT ac DOT uk> |
<CAM2RGhTP4tMk_=-o3-K_pss38AF+f_vd46T=jC4+4RdMXWnWSw AT mail DOT gmail DOT com> | |
<8376edcac9694d2dc0d4195b4810ff45 AT cam DOT ac DOT uk> | |
Date: | Fri, 3 Jul 2015 22:16:51 +0000 |
Message-ID: | <CAM2RGhRA6fjK8uPboNRnWSA4w-St_B91Dsbp04ZHehy1Dj3z8w@mail.gmail.com> |
Subject: | Re: [geda-user] OFFTOPIC: New toy... |
From: | "Evan Foss (evanfoss AT gmail DOT com) [via geda-user AT delorie DOT com]" <geda-user AT delorie DOT com> |
To: | geda-user AT delorie DOT com |
Reply-To: | geda-user AT delorie DOT com |
Errors-To: | nobody AT delorie DOT com |
X-Mailing-List: | geda-user AT delorie DOT com |
X-Unsubscribes-To: | listserv AT delorie DOT com |
Ok. It is odd how many people I know use non-isolated probes on things like the 3PH power to the motor. On Fri, Jul 3, 2015 at 9:19 PM, Peter C.J. Clifton <pcjc2 AT cam DOT ac DOT uk> wrote: > On 2015-07-03 05:31, Evan Foss (evanfoss AT gmail DOT com) [via > geda-user AT delorie DOT com] wrote: >> >> Little bit of general advise. Get/fabricate a clamp on probe for this. >> Many an oscilloscope have died trying to fix these kind of things. >> Thankfully none of mine but still. > > > I tend to borrow a HV isolation probe (and current clamp if things really > need to get serious).. but have up to 100:1 'scope probes too, that can help > for power circuits. -- Home http://evanfoss.googlepages.com/ Work http://forge.abcd.harvard.edu/gf/project/epl_engineering/wiki/
webmaster | delorie software privacy |
Copyright © 2019 by DJ Delorie | Updated Jul 2019 |