| www.delorie.com/archives/browse.cgi | search |
| X-Authentication-Warning: | delorie.com: mail set sender to geda-user-bounces using -f |
| X-Recipient: | geda-user AT delorie DOT com |
| Message-ID: | <20150114150259.9925.qmail@stuge.se> |
| Date: | Wed, 14 Jan 2015 16:02:59 +0100 |
| From: | Peter Stuge <peter AT stuge DOT se> |
| To: | geda-user AT delorie DOT com |
| Subject: | Re: [geda-user] Any good repository for datasheets in pdf out |
| there? | |
| Mail-Followup-To: | geda-user AT delorie DOT com |
| References: | <CAGde_xMT+BXsS0iiTD4yz2On_nTpAD1VkyzkKVuGW4=gduOqdg AT mail DOT gmail DOT com> <54B57095 DOT 20000 AT sbcglobal DOT net> <CAGde_xMHch3jiGc=0TR-6aCnVhQ9GfJ+-ozGN2jMaBKwrdB8jQ AT mail DOT gmail DOT com> <20150114114830 DOT GA24995 AT visitor2 DOT iram DOT es> |
| MIME-Version: | 1.0 |
| In-Reply-To: | <20150114114830.GA24995@visitor2.iram.es> |
| Reply-To: | geda-user AT delorie DOT com |
| Errors-To: | nobody AT delorie DOT com |
| X-Mailing-List: | geda-user AT delorie DOT com |
| X-Unsubscribes-To: | listserv AT delorie DOT com |
Gabriel Paubert wrote: > The temperature range was specified as -200C to 260C, they recently > changed the lower end of the temperature range to -70C. .. > Reducing the range of a temperature probe by 130C without even > touching the part number is unacceptable in my eyes I don't expect that they made any change to the probes. They just fixed the documentation. My guess is that your old probes have exactly the same performance as new ones. //Peter
| webmaster | delorie software privacy |
| Copyright © 2019 by DJ Delorie | Updated Jul 2019 |