www.delorie.com/archives/browse.cgi | search |
X-Authentication-Warning: | delorie.com: mail set sender to geda-user-bounces using -f |
Date: | Thu, 6 Mar 2014 16:37:29 -0500 |
Message-Id: | <201403062137.s26LbTxH027482@envy.delorie.com> |
From: | DJ Delorie <dj AT delorie DOT com> |
To: | geda-user AT delorie DOT com |
In-reply-to: | |
<CALSZ9grqOHHqvi3dfSmnBYUtJDhT-FHt=dx7fsJJeSW2JeWkDQ AT mail DOT gmail DOT com> | |
(message from Rob Butts on Thu, 6 Mar 2014 16:32:12 -0500) | |
Subject: | Re: [geda-user] Connecting pins to planes |
References: | <CALSZ9go7F8rsz-jY2EKeO4mhgtpDD45hYzpkxYYgxOzB_eK64Q AT mail DOT gmail DOT com> |
<201403062056 DOT s26Kudar025124 AT envy DOT delorie DOT com> | |
<CALSZ9goR5qRg30wnf-+pxzqhWkc=c52VbARY5PaEtuL9eawLCQ AT mail DOT gmail DOT com> <CALSZ9grqOHHqvi3dfSmnBYUtJDhT-FHt=dx7fsJJeSW2JeWkDQ AT mail DOT gmail DOT com> | |
Reply-To: | geda-user AT delorie DOT com |
> Shift-clicking with the thermal tool just seems to toggle between 45 > degree connects and no connect ~ I can't seem to get to the final no > thermal version in the picture at your link showing the different > thermals. What version of pcb? It wasn't in the original thermal tool, but the new thermal types (there are four) and the no-thermal option have been around for a while. Note: left clicking the tool toggles between thermal-connect and isolated (the first two images). Shift-clicking cycles through the thermal types.
webmaster | delorie software privacy |