| www.delorie.com/archives/browse.cgi | search |
| X-Authentication-Warning: | delorie.com: mail set sender to geda-user-bounces using -f |
| Date: | Tue, 17 Jan 2012 21:55:42 -0500 |
| Message-Id: | <201201180255.q0I2tgu1006960@envy.delorie.com> |
| From: | DJ Delorie <dj AT delorie DOT com> |
| To: | geda-user AT delorie DOT com |
| In-reply-to: | <20120117175302.40e03333@svelte> (message from Colin D Bennett on |
| Tue, 17 Jan 2012 17:53:02 -0800) | |
| Subject: | Re: [geda-user] "Hole too close to pad"/line warning for non-plated through-hole |
| pins | |
| References: | <20120117175302 DOT 40e03333 AT svelte> |
| Reply-To: | geda-user AT delorie DOT com |
| Errors-To: | nobody AT delorie DOT com |
| X-Mailing-List: | geda-user AT delorie DOT com |
| X-Unsubscribes-To: | listserv AT delorie DOT com |
This is a warning for non-plated holes, since those tend to be mechanical holes. Try using a plated hole, but set the hole's copper annulus to less than the drill size, or even zero. I'm not sure if we have exceptions for plated-as-mechanical holes though. Otherwise, hack those messages out of src/find.c :-)