www.delorie.com/djgpp/doc/rbinter/74.html   search  
675C

Category: memory management

INT 67 - LIM EMS 4.0 - PREPARE EXPANDED MEMORY HARDWARE FOR WARM BOOT

	AH = 5Ch
Return: AH = status (see #03663)
Note:	when MS-DOS v6.xx EMM386 is loaded and the keyboard driver supports
	  INT 15/AH=4Fh (keyboard intercept) calls, the system may hang
	  instead of booting if this function is called just prior to a jump
	  to F000h:FFF0h