7F10--CL09

Category: network

INT 7F - Alloy NTNX, MW386 - CHANNEL CONTROL - UNLOCK MULTIPLE CHANNELS

	AH = 10h
	CL = 09h
	DX = maximum channel number to unlock
Return: AL = status (00h-03h) (see #03951)
Notes:	unlocks channels numbered 00h through the value in DX
	may not be invoked from within a hardware interrupt handler
SeeAlso: AH=10h/CL=03h,AH=10h/CL=07h,AH=10h/CL=08h