INT 13 - FIXED DISK - FORMAT TRACK AND SET BAD SECTOR FLAGS (XT,PORT) AH = 06h AL = interleave value CH = cylinder number (bits 8,9 in high bits of CL) CL = sector number DH = head DL = drive Return: AH = status code (see #00234) Note: AWARD AT BIOS and AMI 386sx BIOS have been extended to handle more than 1024 cylinders by placing bits 10 and 11 of the cylinder number into bits 6 and 7 of DH SeeAlso: AH=05h"FIXED",AH=07h"FIXED"