www.delorie.com/djgpp/doc/rbinter/17.html   search  
15DE1C

Category: DESQview/TopView and Quarterdeck programs

INT 15 - DESQview v2.23+ - "ENTERC" - INCREMENT CRITICAL NESTING COUNT

	AX = DE1Ch
Return: nothing
Notes:	similar to AX=101Bh, but begins the critical region without ensuring
	  that DOS is free
	the official documentation states that this call should be paired with
	  "ENDC" (AX=101Ch); no mention is made of AX=DE1Bh
	this API call may be made from within a hardware interrupt handler
SeeAlso: AX=101Bh,AX=101Ch,AX=DE13h,AX=DE1Bh

  webmaster   donations   bookstore     delorie software   privacy  