X-Authentication-Warning: delorie.com: mail set sender to geda-user-bounces using -f X-Recipient: geda-user AT delorie DOT com Date: Mon, 6 Jun 2016 10:04:22 +0200 (CEST) X-X-Sender: igor2 AT igor2priv To: "Lev (leventelist AT gmail DOT com) [via geda-user AT delorie DOT com]" X-Debug: to=geda-user AT delorie DOT com from="gedau AT igor2 DOT repo DOT hu" From: gedau AT igor2 DOT repo DOT hu Subject: Re: [geda-user] "keepaway" vs. "clearance" In-Reply-To: <20160606092408.660e11f0@jive> Message-ID: References: <20160605212647 DOT 0CD3C818B855 AT turkos DOT aspodata DOT se> <20160606092408 DOT 660e11f0 AT jive> User-Agent: Alpine 2.00 (DEB 1167 2008-08-23) MIME-Version: 1.0 Content-Type: TEXT/PLAIN; charset=US-ASCII; format=flowed Reply-To: geda-user AT delorie DOT com Errors-To: nobody AT delorie DOT com X-Mailing-List: geda-user AT delorie DOT com X-Unsubscribes-To: listserv AT delorie DOT com Precedence: bulk On Mon, 6 Jun 2016, Lev (leventelist AT gmail DOT com) [via geda-user AT delorie DOT com] wrote: > Content preview: And... it would be nice if we can specify DRC rules and design > rules in one place. Or at least a button to import design rules to DRC. And... > why is the limitation of 4 design ruleset in PCB file? Lev [...] > > Content analysis details: (2.6 points, 5.0 required) > > pts rule name description > ---- ---------------------- -------------------------------------------------- > 0.0 FSL_HELO_NON_FQDN_1 No description available. > 0.0 DKIM_ADSP_CUSTOM_MED No valid author signature, adsp_override is > CUSTOM_MED > 0.0 FREEMAIL_FROM Sender email is commonly abused enduser mail provider > (leventelist[at]gmail.com) > 1.7 MIME_BASE64_TEXT RAW: Message text disguised using base64 encoding > 0.9 NML_ADSP_CUSTOM_MED ADSP custom_med hit, and not from a mailing list > X-Scan-Signature: 9524fb9e753911cde8111ed9f87fc0b5 > Content-Transfer-Encoding: 8bit > X-MIME-Autoconverted: from base64 to 8bit by delorie.com id u567OPSr020538 > > And... it would be nice if we can specify DRC rules and design rules in > one place. Or at least a button to import design rules to DRC. The vendor drill stuff can do that (from a resource file, overwriting PCB data stuff). (pcb-rnd's new config system (WIP) is more flexible, it will also be possible to replace settings partially from files.) > > And... why is the limitation of 4 design ruleset in PCB file? It's a random limit that can be changed compile-time. AFAIK raising it might cause compatibility problems, tho: if you open the design with 16 styles with a pcb that has a limit of 4 and save, it will probably remove all styles above 4. (I have plans to rewrite this part to be dynamic in pcb-rnd as part of the config rewrite.) Regards, Igor2