X-Authentication-Warning: delorie.com: mail set sender to geda-user-bounces using -f X-Recipient: geda-user AT delorie DOT com X-Original-DKIM-Signature: v=1; a=rsa-sha256; c=relaxed/relaxed; d=gmail.com; s=20120113; h=mime-version:in-reply-to:references:date:message-id:subject:from:to :content-type; bh=DEi2xoIKEA0q6VXAezOphHEv2BT6bcLGPbQB+KuoSKs=; b=fH/dUyRSO0QZZl/Md2cgSUUb/xpkHyJdmy3ifYEFprhcXL8TRr+q2JqRzUyv+Tl8Vx KPJmA8kkFzsGL5DiDVrWI8Z0Y2a+IKi4PMjfqMfBIykKgeHzBsmynZq53gJ+6cLejxfS TeswQpfYjlP3fTYmUQinG4UDBY5TSpEUmtEaOkCTAk7vlLgUkmTIWzAyhpNj5WdpNtkV jBbR3DAadrWpN0fAsHAsAaI14O5T2HrT2smzCGYgBM1vKR21DlEFgSOX/kE1sVQjXQAx z18Xk4bPBYy0frko4U1vpV84GZIU6t+L2qsdXdKKrsA2a0bxRSXOhUNN9ide2b+tM1J9 S+Rw== MIME-Version: 1.0 X-Received: by 10.31.155.5 with SMTP id d5mr8580329vke.121.1442147178459; Sun, 13 Sep 2015 05:26:18 -0700 (PDT) In-Reply-To: References: Date: Sun, 13 Sep 2015 17:56:18 +0530 Message-ID: Subject: Re: [geda-user] Connecting grounds From: "Shashank Chintalagiri (shashank DOT chintalagiri AT gmail DOT com) [via geda-user AT delorie DOT com]" To: geda-user AT delorie DOT com Content-Type: text/plain; charset=UTF-8 Reply-To: geda-user AT delorie DOT com Errors-To: nobody AT delorie DOT com X-Mailing-List: geda-user AT delorie DOT com X-Unsubscribes-To: listserv AT delorie DOT com Precedence: bulk When I use separate grounds, they're usually derived from isolated supplies. This keeps the currents between the grounds minimal, so I keep solder dots or the like between grounds, and short them with solder dots or 0 ohm resistors on the fabricated PCB. This allows my PCB file to stay 'clean' with the separate ground polygons and makes debugging a lot easier. If you're making the various grounds from a star at a single source, admittedly this approach may not be ideal. It still could work with a well-soldered 0ohm resistor, as long as the impedance of the resistor (and the solder joints, etc.) is not too different from, say, the impedance of whatever your original ground source is. On Sun, Sep 13, 2015 at 5:43 AM, Hannu Vuolasaho (vuokko AT msn DOT com) [via geda-user AT delorie DOT com] wrote: > > > Evan Foss wrote: >> >> Right now there is no way to do this. In fact John Doty and I are >> debating it in the other thread. >> > > I noticed that but I thought it was about busses. > > Anyway I believe DJ's and John Doty's work will help me > out from this. The tools are there to use already. > > I'll follow DJ's advice and not connect those grounds yet. > > Some time ago I asked about gnetlist backend which would > take input and output symbols. Then it would generate djboxsym > file. > > I'll just have ground.sch and add output symbol every time I > need a new ground and makefile shall update symbol on my > top level. Only negative side is that I have to bring grounds through > everything or use netname to connect it. > > When everything is set up I'll connect everything in ground.sch. > > That way risk of using wrong ground is much smaller. > > Hannu Vuolasaho > -- Chintalagiri Shashank Indian Institute of Technology, Kanpur http://blog.chintal.in