X-Authentication-Warning: delorie.com: mail set sender to geda-user-bounces using -f X-Recipient: geda-user AT delorie DOT com Date: Thu, 20 Oct 2011 10:45:41 -0700 From: Andrew Poelstra To: geda-user AT delorie DOT com Subject: Re: [geda-user] Working with a 0.1mm grid Message-ID: <20111020174541.GD20384@malakian.lan> References: <201110201548 DOT p9KFma9K019672 AT envy DOT delorie DOT com> <20111020172714 DOT GB20384 AT malakian DOT lan> <201110201730 DOT p9KHUh51023430 AT envy DOT delorie DOT com> MIME-Version: 1.0 Content-Type: text/plain; charset=us-ascii Content-Disposition: inline In-Reply-To: <201110201730.p9KHUh51023430@envy.delorie.com> User-Agent: Mutt/1.5.20 (2009-12-10) Reply-To: geda-user AT delorie DOT com Errors-To: nobody AT delorie DOT com X-Mailing-List: geda-user AT delorie DOT com X-Unsubscribes-To: listserv AT delorie DOT com Precedence: bulk On Thu, Oct 20, 2011 at 01:30:43PM -0400, DJ Delorie wrote: > > > No, it's the "only use cmils for backward compatibility" code. > > Older PCBs don't understand units on the Grid[] data ? They understand: no units means cmils "mm" suffix means mm "mil" suffix means mil Some other suffixes are in the code, but IIRC, the scale factors are backward so they don't work. -- Andrew Poelstra Email: asp11 at sfu.ca OR apoelstra at wpsoftware.net Web: http://www.wpsoftware.net/andrew